최신Autodesk Certified Professional in Revit for Electrical Design - RVT_ELEC_01101무료샘플문제
문제1
An electrical designer is routing conduit through a building model to coordinate with other disciplines, the electrical designer wants to view selected components in a cropped 3D view.
With the conduit components selected, which tool should the designer use?
An electrical designer is routing conduit through a building model to coordinate with other disciplines, the electrical designer wants to view selected components in a cropped 3D view.
With the conduit components selected, which tool should the designer use?
정답: C
설명: (KoreaDumps 회원만 볼 수 있음)
문제2
Refer to exhibit.

Why is one receptacle shown in full color (black) and one receptacle shown in halftone (gray)?
Refer to exhibit.

Why is one receptacle shown in full color (black) and one receptacle shown in halftone (gray)?
정답: C
설명: (KoreaDumps 회원만 볼 수 있음)
문제3
Refer to exhibit.
A panelboard has the following properties:

The Circuit Naming Scheme PanelSlolPhase. which defines the value of the Circuit Number parameter, is configured as follows:

In electrical settings. Phase Labels have not been modified from the default "A." "B." and "C- The Circuit Number lot a single-pole circuit in the panelboard's first breaker position is----------(Enter the correct value into the field)
Refer to exhibit.
A panelboard has the following properties:

The Circuit Naming Scheme PanelSlolPhase. which defines the value of the Circuit Number parameter, is configured as follows:

In electrical settings. Phase Labels have not been modified from the default "A." "B." and "C- The Circuit Number lot a single-pole circuit in the panelboard's first breaker position is----------(Enter the correct value into the field)
정답:
See the explanation
Explanation:
The answer is P1/1/A
In Autodesk Revit Electrical Design, the Circuit Number for a branch circuit in a panelboard is automatically generated based on the Circuit Naming Scheme specified in the project's Electrical Settings. This naming scheme defines how each circuit is labeled by combining predefined fields such as Panel Name, Slot Index, and Phase Label.
From the exhibit, the Circuit Naming Parameter setup is configured as:
Name
Prefix
Sample Value
Suffix
Separator
Panel
Panel
Panel
-
"-"
Slot Index
Slot Index
Slot Index
-
"/"
Phase Label
Phase Label
Phase Label
-
-
The panelboard properties show that its Circuit Naming method is set to PanelSlotPhase, which means that Revit will generate circuit numbers using the following structure:
[Panel Name] - [Slot Index] / [Phase Label]
From the exhibit:
Panel Name: P1
Slot Index (Breaker Position): 1 (since the question refers to the first breaker position) Phase Label: A (default value for the first phase in a three-phase 120/208V Wye system) Therefore, the Circuit Number for a single-pole circuit in the first breaker slot will be:
✅ P1-1/A
This follows Revit's documented logic for circuit naming. According to the Autodesk Revit MEP User's Guide (Chapter 17 "Electrical Systems"):
"The circuit numbering format is controlled by the Electrical Settings > Circuit Naming template. The default scheme combines panel name, circuit number, and phase label, using the separators defined by the user." Furthermore, the Smithsonian Facilities Revit Template User's Guide confirms:
"In the default electrical configuration, circuit numbers use the format [Panel Name]-[Circuit Number]/[Phase], such as 'P1-1/A' for the first single-pole circuit on phase A." Hence, based on the provided configuration and standard electrical setup, the correct circuit number for the first single-pole breaker position in panelboard P1 is P1-1/A.
References:
Autodesk Revit MEP User's Guide - Chapter 17 "Electrical Systems," pp. 420-427 Smithsonian Facilities Revit Template User's Guide - Section 8.6 "Panel Schedules and Circuit Naming Schemes," p. 90 Autodesk Revit Electrical Design Essentials - "Circuit Naming Rules and Panel Configuration Standards"
Explanation:
The answer is P1/1/A
In Autodesk Revit Electrical Design, the Circuit Number for a branch circuit in a panelboard is automatically generated based on the Circuit Naming Scheme specified in the project's Electrical Settings. This naming scheme defines how each circuit is labeled by combining predefined fields such as Panel Name, Slot Index, and Phase Label.
From the exhibit, the Circuit Naming Parameter setup is configured as:
Name
Prefix
Sample Value
Suffix
Separator
Panel
Panel
Panel
-
"-"
Slot Index
Slot Index
Slot Index
-
"/"
Phase Label
Phase Label
Phase Label
-
-
The panelboard properties show that its Circuit Naming method is set to PanelSlotPhase, which means that Revit will generate circuit numbers using the following structure:
[Panel Name] - [Slot Index] / [Phase Label]
From the exhibit:
Panel Name: P1
Slot Index (Breaker Position): 1 (since the question refers to the first breaker position) Phase Label: A (default value for the first phase in a three-phase 120/208V Wye system) Therefore, the Circuit Number for a single-pole circuit in the first breaker slot will be:
✅ P1-1/A
This follows Revit's documented logic for circuit naming. According to the Autodesk Revit MEP User's Guide (Chapter 17 "Electrical Systems"):
"The circuit numbering format is controlled by the Electrical Settings > Circuit Naming template. The default scheme combines panel name, circuit number, and phase label, using the separators defined by the user." Furthermore, the Smithsonian Facilities Revit Template User's Guide confirms:
"In the default electrical configuration, circuit numbers use the format [Panel Name]-[Circuit Number]/[Phase], such as 'P1-1/A' for the first single-pole circuit on phase A." Hence, based on the provided configuration and standard electrical setup, the correct circuit number for the first single-pole breaker position in panelboard P1 is P1-1/A.
References:
Autodesk Revit MEP User's Guide - Chapter 17 "Electrical Systems," pp. 420-427 Smithsonian Facilities Revit Template User's Guide - Section 8.6 "Panel Schedules and Circuit Naming Schemes," p. 90 Autodesk Revit Electrical Design Essentials - "Circuit Naming Rules and Panel Configuration Standards"
문제4
An electrical designer needs to directly connect panel B to panel A without a breaker. Panel A's load must reflect the entire load from panel B. Which conditions must be met to ensure that panel B is correctly connected to panel A?
An electrical designer needs to directly connect panel B to panel A without a breaker. Panel A's load must reflect the entire load from panel B. Which conditions must be met to ensure that panel B is correctly connected to panel A?
정답: A
설명: (KoreaDumps 회원만 볼 수 있음)
문제5
Which feature shows which user created 3n element?
Which feature shows which user created 3n element?
정답: D
설명: (KoreaDumps 회원만 볼 수 있음)
문제6
What two ways can an electrical designer copy a cable tray type from a project to a template? (Select two.)
What two ways can an electrical designer copy a cable tray type from a project to a template? (Select two.)
정답: B,C
설명: (KoreaDumps 회원만 볼 수 있음)
문제7
An electrical designer receives an architectural model and links it into the electrical model.
The designer wants to use the Copy/Monitor tool to copy the exact electrical fixtures created by the architect.
The designer also wants the software to automatically detect new electrical fixtures added to the architectural model.
Select the correct coordination settings from the drop-down lists

An electrical designer receives an architectural model and links it into the electrical model.
The designer wants to use the Copy/Monitor tool to copy the exact electrical fixtures created by the architect.
The designer also wants the software to automatically detect new electrical fixtures added to the architectural model.
Select the correct coordination settings from the drop-down lists

정답: